Polymex P-5032 2K Solvent Free Epoxy Sound Insulation Topcoat Paint

Two-component, solvent-free epoxy and special filler additives Epoxy-based glossy or matt first coat and top coat paint, absolutely solvent-free

Reduces heating and cooling requirements throughout the year.

%40-%50 arası enerji tasarrufu sağlar.

Ses yalıtımında %40-%50 etkilidir.

Sound Thermal Insulation Coating Paint

Solar ışınların %99,8 ini reflekte eder ve yüzeye nüfuz etmesini engeller.

It increases comfort indoors and the applied surfaces turn into heat barriers.

It completely stops moisture, condensation and mold.

It provides excellent adhesion on surfaces and is very effective in closing cracks.

It is waterproof.

It is a non-toxic product, leaving no lead pigment.

Ready for use.

% 100 is elastic.

Tensile strength 23 after 24 hours o24.5 kgf/cm at C2 55 kgf/cm after 72 hours2

It is applied with Brush Roller Trowel.

It is not affected by sunlight.

It retains its elasticity even at low temperatures.

Provides high adherence.

Easy and fast to apply.

Resistant to freeze-thaw cycles.

ColorWhite-Grey-Cream-Desired Color
Elasticity %100
Density1.40 gr/ml
ConsistencyBrush, Roller consistency, semi-fluid liquid
Application EquipmentRoller, Brush, Trowel, Check Pass
Applicable Floor Temperature 5-35 oC
Adhesion Strength12 kgf/cm2
Thermal Insulation Coating Drying timeFirst drying 12 hours, second coat 24 hours (Full drying 48 hours)
Physical and Chemical resistanceIt starts 7 days after application.
Thermal Insulation Coating CombustionThe retarder does not emit any toxic gas.
Thermal Insulation Coating Health compatibilityAfter complete drying it is absolutely not harmful to health.
UV It is durable.
Material Flash Temperature Flash Point CoatingAt least 190 oC 214/F.VOC 0.60 Gram/Ltr.

Usage Areas:
P-5032-Solvent-free epoxy sound insulation floor topcoat paint It is used as floor and wall coating in refineries, petrochemical and other industrial establishments, ports and shipyards, drinking water and fuel tanks, treatment and waste water facilities, wine storage tanks, food industry, hospitals and pharmaceutical industry, laboratories, textile and automotive industry in order to protect concrete and metal surfaces from atmospheric and chemical effects.

Implementation:

P-5032-Solvent Free Epoxy Sound Insulation Floor Topcoat Paint After mixing the base material, add hardener and mix for 2-3 minutes until homogenous. After resting the mixture for 3 minutes, proceed with the application. Do not prepare more material than the amount that can be applied during the life of the mixture.

Terms of Application:

Solvent-free epoxy sound insulation floor topcoat New concrete and cement plaster should be cured for at least 14 days. After the mortar residue etc. on the cured surface is removed by light sandblasting or brushing, the selected primer is applied. Loose particles such as old paint, dirt, dust etc. on the old concrete and cement plaster surface are removed by sandblasting, scraping, brushing. Oil and grease residues are cleaned with detergent water, if neutralization is required, the surface is wiped with % 3-4% hydrochloric acid or acetic acid solution and washed with water. Make sure that the surface is completely dry before applying the selected primer.

Consumption: 

For 1 mm dry film thickness: 1.2.kg/m2

For 1 mm wet film thickness: 1.3 kg/m2

Floor paint, exterior and interior coatings: 0.500 gram/m2

Solvent Free Epoxy Sound Insulation Topcoat Paint

 

Application Methods:

Apply with a short nap roller, comb trowel or Airless Spray.

 

Application Temperature:

Do not apply below +10 °C.

Mixture Lifetime:

1 hour at 23 °C. Mix life shortens as the amount of mixture and ambient temperature increases. Solvent Free Epoxy Sound Insulation Topcoat Paint

Waiting Between Floors:

Minimum 6 and maximum 48 hours. If this time period is exceeded, the floor should be roughened with sandpaper for good adhesion.

 

Drying Time:

Surface drying at 20°C: 6-8 hours; complete drying at 20°C: 16-24 hours

Solvent Free Epoxy Sound Insulation Topcoat Paint

Curing

7 days at 20°C. During this period, the paint film should not be exposed to any chemical and mechanical effects. Solvent Free Epoxy Sound Insulation Topcoat Paint

Thinning and Cleaning:

When used as a primer on absorbent concrete surfaces, dilute with % 15 special thinner by weight.

Consumption:
Theoretically, approximately 250 g/m in a single layer with a film thickness of 125 microns(Depends on the roughness of the surface)

Considerations:

Mix until homogenized before use. Apply between + 7 °C and + 35 °C. Protect the product from freezing and hot weather.

Notes
All technical data contained in this product data sheet are based on laboratory experiments. Actual data may vary due to conditions beyond the control of AŞY POLYMEKS KİMYA SAN TİC LTD ŞTİ.